141
TERMINAL CONFIGURATION
F1. CALL AT NUMBER OF JOURNAL RECORDS. This function sets the number of journal records that will
automatically trigger a notification message to a remote Triton Connect computer.
! Press <F1> on the function keys. A data entry dialog box appears. Enter the number of journal
records to issue a Triton Connect call using a value between ‘1’ and ‘99999’. Press <E
NTER> when
completed.
Note: Enter zero <0> to
disable this function.
F2. C
ALL AT LOW CASH THRESHOLD. This function allows you to enter the number of notes in a cassette
that will automatically trigger a low cash notification message to a remote Triton Connect computer.
! Press <F2> on the function keys. A data entry dialog box appears. Enter the low cash threshold in
total number of bills left that will trigger a low cash level. Use a value between ‘1’ and ‘99999’. Press
<ENTER> when completed.
Note: Enter zero <0> to
disable this function.
F3. E
NTER NEW ACCESS CODE. Enter a six (6)-digit code that a Triton connect host computer must use
when calling the terminal to perform software downloads/updates. If the code used does not match
this code entered, the terminal will not allow the software download to be performed.
! Press <F3> on the function keys. A data entry dialog box appears. Enter the 6-digit access code.
Press <ENTER> when completed.