X-SCALE / X2 CONFIGURATION MANUAL
KEYPAD
ACCESS INSTRUCTIONS:
1. From the D
IAGNOSTICS screen, select the KEYPAD option by pressing <8> on the keypad.
2. From the KEYPAD screen, select the DEVICE STATUS option by pressing <1> on the keypad.
3. From the K
EYPAD screen, select the TEST option by pressing <2> on the keypad.
D
ESCRIPTION:
The DEVICE STATUS displays a management report that shows infor-
mation such as keypad status, serial number, version number, and
loaded encrypted key check digits.
The T
EST function enables you to verify operation of the numeric,
function, and control buttons on the terminal. Simply press any but-
ton (except the <Enter> button) and the status window will indicate
the state of the button: Up or Down. Press the <E
NTER> button when
completed.
* NOTE *
In the event the terminal displays Error Codes
ranging from 592-617 (keypad specific), op-
tion <4> in the Keypad functions may be an
available option. If it is, attempt to clear the
error by selecting this option.
Clear Serial #
Error
4
Keypad/Screen Button Test
Press ENTER to Quit
Keypad 1, State: Down
Keypad 1, State: Up
Screen Button 1, State Down
Screen Button 1, State: up
The CLEAR SERIAL # OR TAMPER ERROR function
may be accessed if you have encountered either a
SPED Serial # error (617 - usually when keypad has
been replaced) or if a Tamper condition has occured.
Press option <4> (if available) to attempt clearing
either of these error conditions.