X-SCALE / X2 CONFIGURATION MANUAL
CASSETTE CLOSE
ACCESS INSTRUCTIONS:
1. From the T
ERMINAL CLOSE FUNCTIONS screen, select the CASSETTE CLOSE option by pressing <6> on
the keypad (or select CASSETTE CLOSE on the REAR SERVICE PANEL, if applicable).
DESCRIPTION:
The CASSETTE CLOSE function is used to complete the balancing of a specific currency cassette(s) of the
terminal. This function displays a report summarizing all activity on the cash dispenser for the selected
cassette(s) since the last cassette close was completed. The report includes a total of all transactions.
The cassette close is normally completed as the final step in balancing a currency cassette before removing
it to be replenished. Completing a cassette close CLEARS the cassette totals from the terminal.
The Cassette Close report is displayed in a management report dialog which can be printed to the receipt
printer or saved to an external memory device.
Select the cassette(s) to Close. A checkmark
identifies which cassette(s) are selected. Press
<ENTER>.
A CLOSE report is presented to be either printed
or saved. Close operation also resets the number
of bills loaded to zero (0). Press <ENTER> to
continue.