Triton X-SCALE/X2 Configuration Manual Manual de usuario Pagina 338

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 419
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 337
Introduction
This document describes new functionality for the 2.0.1 software release for RL2000, RL5000,
FT5000, and RT2000 with X2 controller for US, Canada, Australia, and Mexico. The
differences described are from XScale 1.8.6.
Platforms Affected
This release is for the following families:
RL2000, RL5000, FT5000, RT2000 with X2 Controller
Hardware Requirements
The following is a list of hardware supported by this software:
Display: 10.4” Color VGA
Card Reader: Magtek 215 Dip Reader, MagTek Intellistripe 65 Dip Reader, or Sankyo
ICT3K5 Motorized Reader
EPP: Triton SP-05 or SP-06.00
Dispenser: TDM50, TMD1xx, TDM2xx, SDD, MiniMech, NMD50, NMD100
Printer: Seiko 80mm USB Printer with Presenter
Modem: Triton USB Modem or MultiTech USB Modem
Software Requirements
The following load files are included with this release:
xd10xcsf2.0.1.tfv – US, Canada, Australia, Mexico Software for 10.4" display
External Dependencies
The following feature requires Triton Connect Version 4.4 or greater:
Software updates from Triton Connect.
X2 2.0.1 Software Release Notes
Triton Systems Page 3 of 19 October 23, 2007