35
DIAGNOSTICS
INJECT NEW CASSETTE ID (NMD ONLY)
ACCESS INSTRUCTIONS:
1. From the D
IAGNOSTICS screen, select the CASH DISPENSER option by pressing <1> on the keypad.
2. From the CASH DISPENSER screen, select the INJECT NEW CASSETTE ID option by pressing <4> on the
keypad.
DESCRIPTION:
The NMD dispensing mechanisms use cassettes that possess onboard memory. This memory enables a
cassette to store its own identification (ID) code.
The I
NJECT NEW CASSETTE ID function has no direct correlation to the physical position of the cassette within
the unit. In most instances, the cassette identified as “A” will be placed in the top feed channel, “B” in the
second, and continuing. This is not a requirement since the ID code allows the dispensing mechanism (and
the dispensers central controller) to locate the cassette wherever it’s been placed in the dispenser.
This function allows injecting a new ID into a cassette. Insert the cassette you want to ID into the
top feed
channel. Press the button corresponding to the identity you want the cassette to have: ‘A’, ‘B’, ‘C’, or ‘D’.
When the ID has successfully been injected, a message prompt will appear. If the operation fails, an error
message will appear. After successfully completing the ID injection, you can place the cassette in its normal operating
position.